TEST 1: Locate your magnetron and label each of the wires attached to it so that you know which wires are to be replaced where. Set your ohmmeter to the lowest resistance scale. Take a resistance measurement between each of the magnetron’s terminals by touching each probe to one terminal each. Reverse the probes and take a second resistance measurement. Each measurement should read less than one ohm.
TEST 2: Set your ohmmeter to its highest resistance scale. Touch one of the meter’s probes to a magnetron terminal. Touch the other probe to the metal magnetron housing. Take special caution to not touch the two probes together. This could result in an inaccurate reading. This test should produce a reading of infinity – indicating an open circuit.
Last Updated on August 28, 2021 by HelpDesk
Was this helpful?
0 / 0